| SetupLoadConfigurationExtensionsWriteToConsole Method |
Namespace:
NLog
Assembly:
NLog (in NLog.dll) Version: 5.3.4+73d83d3161d31288ca5c554cc50d27b6bed5f28b
Syntax public static ISetupConfigurationTargetBuilder WriteToConsole(
this ISetupConfigurationTargetBuilder configBuilder,
Layout layout = null,
Encoding encoding = null,
bool stderr = false,
bool detectConsoleAvailable = false,
bool writeBuffered = false
)
<ExtensionAttribute>
Public Shared Function WriteToConsole (
configBuilder As ISetupConfigurationTargetBuilder,
Optional layout As Layout = Nothing,
Optional encoding As Encoding = Nothing,
Optional stderr As Boolean = false,
Optional detectConsoleAvailable As Boolean = false,
Optional writeBuffered As Boolean = false
) As ISetupConfigurationTargetBuilder
Dim configBuilder As ISetupConfigurationTargetBuilder
Dim layout As Layout
Dim encoding As Encoding
Dim stderr As Boolean
Dim detectConsoleAvailable As Boolean
Dim writeBuffered As Boolean
Dim returnValue As ISetupConfigurationTargetBuilder
returnValue = configBuilder.WriteToConsole(layout,
encoding, stderr, detectConsoleAvailable,
writeBuffered)
[<ExtensionAttribute>]
static member WriteToConsole :
configBuilder : ISetupConfigurationTargetBuilder *
?layout : Layout *
?encoding : Encoding *
?stderr : bool *
?detectConsoleAvailable : bool *
?writeBuffered : bool
(* Defaults:
let _layout = defaultArg layout null
let _encoding = defaultArg encoding null
let _stderr = defaultArg stderr false
let _detectConsoleAvailable = defaultArg detectConsoleAvailable false
let _writeBuffered = defaultArg writeBuffered false
*)
-> ISetupConfigurationTargetBuilder
Parameters
- configBuilder
- Type: NLog.ConfigISetupConfigurationTargetBuilder
Fluent interface parameter. - layout (Optional)
- Type: NLog.LayoutsLayout
Override the default Layout for output - encoding (Optional)
- Type: System.TextEncoding
Override the default Encoding for output (Ex. UTF8) - stderr (Optional)
- Type: SystemBoolean
Write to stderr instead of standard output (stdout) - detectConsoleAvailable (Optional)
- Type: SystemBoolean
Skip overhead from writing to console, when not available (Ex. running as Windows Service) - writeBuffered (Optional)
- Type: SystemBoolean
Enable batch writing of logevents, instead of Console.WriteLine for each logevent (Requires WithAsync(ISetupConfigurationTargetBuilder, AsyncTargetWrapperOverflowAction, Int32, Int32))
Return Value
Type:
ISetupConfigurationTargetBuilderUsage Note
In Visual Basic and C#, you can call this method as an instance method on any object of type
ISetupConfigurationTargetBuilder. When you use instance method syntax to call this method, omit the first parameter. For more information, see
Extension Methods (Visual Basic) or
Extension Methods (C# Programming Guide).
See Also